Within the specified working pressure range, the opening pressure can be adjusted by rotating the adjusting screw and changing the spring preload compression amount. Remove the Universal Valve cover cap, loosen the locking nut, and then adjust the adjusting screw. First, increase the inlet pressure to make the Universal Valve jump once. If the opening pressure is low, tighten the adjusting screw clockwise. ; If the opening pressure is too high, loosen it counterclockwise. After adjusting to the required opening pressure, tighten the locking nut and install the cover.
In order to ensure that the opening pressure value is accurate, the medium conditions used during adjustment, such as medium type and medium temperature, should be as close as possible to the actual working conditions. When the type of medium changes, especially when changing from liquid phase to gas phase, the opening pressure often changes. As the operating temperature increases, the opening pressure decreases. Therefore, when adjusting at normal temperature and using it at high temperature, the set pressure value at normal temperature should be slightly larger than the opening pressure value of the ball.
LET'S GET IN TOUCH
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.